
<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>CADTEC</title>
	<atom:link href="http://www.cadtec.it/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.cadtec.it</link>
	<description>Soluzioni PDM-PLM</description>
	<lastBuildDate>Fri, 18 May 2012 12:48:03 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.2</generator>
		<item>
		<title>Pro.File si classifica al primo posto in una comparativa tra PLM</title>
		<link>http://www.cadtec.it/pro-file/8-3/pro-file-si-classifica-al-primo-posto-in-una-comparativa-tra-plm/</link>
		<comments>http://www.cadtec.it/pro-file/8-3/pro-file-si-classifica-al-primo-posto-in-una-comparativa-tra-plm/#comments</comments>
		<pubDate>Tue, 24 Apr 2012 14:55:09 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[2011]]></category>
		<category><![CDATA[8.3]]></category>
		<category><![CDATA[Classifiche]]></category>
		<category><![CDATA[PLM]]></category>
		<category><![CDATA[Premi]]></category>

		<guid isPermaLink="false">http://www.cadtec.it/index.php/?p=402</guid>
		<description><![CDATA[Bridges and other buildings are also products. Similar to mechanical engineering and construction, CAD models and documents have to be administered and processes have to be documented. The Bavarian Research Alliance, in cooperation with the Institute of Materials Handling, Material Flow, Logistics at Technical University Munich, Germany, has tested PDM systems for their suitability for&#160;<a href="http://www.cadtec.it/pro-file/8-3/pro-file-si-classifica-al-primo-posto-in-una-comparativa-tra-plm/" class="read-more">Continue Reading</a>]]></description>
			<content:encoded><![CDATA[<p><strong>Bridges and other buildings are also products. Similar to mechanical engineering and construction, CAD models and documents have to be administered and processes have to be documented.</strong></p>
<p><span id="more-762"></span></p>
<p>The Bavarian Research Alliance, in cooperation with the Institute of Materials Handling, Material Flow, Logistics at Technical University Munich, Germany, has tested PDM systems for their suitability for building and civil engineering. The PDM systems were tested for the usage in central data administration of AutoCAD drawings and 3D models of buildings in the context of the ForBau project. The results of the comparison were published in February in a detailed study.</p>
<p>PRO.FILE PLM of PROCAD ranked first place in this comparison. Eleven technical criteria were used for the evaluation. PRO.FILE scored best in the categories user ergonomics, administration and customizing, as well as process management. Also in the categories general data management, interfaces and rights/roles/user management, PRO.FILE was not topped by any other system.</p>
<p>Based on this ranking, Technical University Munich selected PRO.FILE for the data management in their large research project ForBAU. The efficiency of the PDM usage in building and civil engineering was demonstrated at the ForBAU final presentation on February 17, with more than 170 visitors. The two project engineers Prof. André Borrmann and Markus Schorr showed in a live presentation how a building project can be handled, from parametric 3D planning to the simulation of execution processes to the recording of the construction progress, with all data being managed centrally in a product data management system.</p>
<p>Details on the study &#8220;Data management in construction&#8221; <img src="http://www.procad.de/image/image_all/link.gif" alt="" width="15" height="8" border="0" /><a href="http://www.fml.mw.tum.de/forbau/index.php?Set_ID=495" target="_blank">Link</a></p>
<p>Dettagli relativi al progetto ForBAU  <img src="http://www.procad.de/image/image_all/link.gif" alt="" width="15" height="8" border="0" /><a href="http://www.fml.mw.tum.de/forbau/index.php?Set_ID=15" target="_blank">Link</a></p>
<p>Link alla notizia sul sito ufficiale di Procad <img src="http://www.procad.de/image/image_all/link.gif" alt="" width="15" height="8" border="0" /><a title="Procad" href="http://www.procad.de/en/" target="_blank">Click</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/pro-file/8-3/pro-file-si-classifica-al-primo-posto-in-una-comparativa-tra-plm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Cadtec &#8230; perchè ?</title>
		<link>http://www.cadtec.it/generale/cadtecperche/</link>
		<comments>http://www.cadtec.it/generale/cadtecperche/#comments</comments>
		<pubDate>Tue, 24 Apr 2012 07:58:09 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[Generale]]></category>

		<guid isPermaLink="false">http://www.cadtec.it/?p=985</guid>
		<description><![CDATA[Avere Cadtec Srl come Partner nell&#8217;adozione di sistemi PDM/PLM significa 1. Analisi precisa ed attenta delle esigenze in fase di prevendita. 2. Operatività fin da subito grazie ai Test di Progetto. 3. Implementazione corretta, sicura e produttiva. &#160; Ti garantiamo 1. Un valido supporto nel pre-vendita grazie all’analisi di fattibilità dell’introduzione di un sistema PDM-PLM.&#160;<a href="http://www.cadtec.it/generale/cadtecperche/" class="read-more">Continue Reading</a>]]></description>
			<content:encoded><![CDATA[<h2>Avere Cadtec Srl come Partner nell&#8217;adozione di sistemi PDM/PLM significa</h2>
<p><span style="color: #ff0000;"><span style="color: #000000;">1.</span> Analisi precisa ed attenta delle esigenze in fase di prevendita.</span></p>
<p><span style="color: #ff0000;"><span style="color: #000000;"> 2.</span> Operatività fin da subito grazie ai Test di Progetto.</span></p>
<p><span style="color: #ff0000;"><span style="color: #000000;"> 3.</span> Implementazione corretta, sicura e produttiva.</span></p>
<p>&nbsp;</p>
<h2>Ti garantiamo</h2>
<p>1. Un valido supporto nel pre-vendita grazie all’analisi di fattibilità dell’introduzione di un sistema PDM-PLM.</p>
<p>2. Implementazione step by step con formula “<strong><span style="color: #333399;">Chiavi in mano</span></strong>”.</p>
<p>3. Un <strong><span style="color: #333399;">aiuto</span></strong> costante nel <strong><span style="color: #333399;">post-vendita</span></strong>, grazie alla formazione del personale e alla gestione dell’assistenza anche da remoto.</p>
<p style="text-align: justify;">Fin da subito con un modesto investimento iniziale in termini di tempo e risorse verrà fornito lo strumento più potente per intraprendere un percorso di ottimizzazione dei processi aziendali produttivo fin da subito.</p>
<h2>Cosa ci distingue?</h2>
<p style="text-align: justify;">Ciò che ci distingue da un semplice fornitore è la capacità di interpretare correttamente le richieste e di accompagnarvi come un Partner.Se poi si riesce anche ad anticipare e a superare le aspettative riposte, allora siamo sicuramente molto più di un Partner.</p>
<p style="text-align: justify;">Dall&#8217;ascolto attento delle singole esigenze alla proposta della soluzione PDM/PLM mirata, Cadtec lavora con passione e professionalità a fianco del tuo team per studiare il risultato migliore garantendo un servizio <strong><span style="color: #333399;">completo</span>, <span style="color: #333399;">efficiente</span>, <span style="color: #333399;">tempestivo</span> e <span style="color: #333399;">vantaggioso</span> </strong>sul piano economico.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/generale/cadtecperche/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Assistenza 24/7</title>
		<link>http://www.cadtec.it/generale/assistenza2/</link>
		<comments>http://www.cadtec.it/generale/assistenza2/#comments</comments>
		<pubDate>Tue, 24 Apr 2012 07:26:50 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[Generale]]></category>

		<guid isPermaLink="false">http://www.cadtec.it/?p=978</guid>
		<description><![CDATA[L&#8217;evasione della sua richiesta è per noi prioritaria. Di seguito le modalità a disposizione: Connessione al portale di assistenza Portale assistenza Cadtec &#8211; Techcenter Per richiedere supporto le ricordiamo di accedere al Techcenter e solo al primo accesso cliccare su New User compilando le informazioni necessarie all&#8217;inserimento del Ticket. &#160; Connessione con un tecnico Immettere&#160;<a href="http://www.cadtec.it/generale/assistenza2/" class="read-more">Continue Reading</a>]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"><strong>L&#8217;evasione della sua richiesta è per noi prioritaria.</p>
<p>Di seguito le modalità a disposizione:</strong></p>
<div>
<h3 style="text-align: center;"><span style="font-size: x-small;"><span style="font-weight: normal;"><br />
</span></span></h3>
<h3 style="text-align: center;"><span style="color: #333399;">Connessione al portale di assistenza</span></h3>
</div>
<div>
<p style="text-align: center;">Portale assistenza Cadtec &#8211; <a class="wp-caption-text" title="Portale Assistenza Cadtec" href="http://88.149.153.178/customer50" target="_blank">Techcenter</a></p>
</div>
<p style="text-align: center;"><em>Per richiedere supporto le ricordiamo di accedere al Techcenter e solo al primo accesso cliccare su New User compilando le informazioni necessarie all&#8217;inserimento del Ticket.</em></p>
<p>&nbsp;</p>
<div>
<h3 style="text-align: center;"><span style="color: #ff0000;">Connessione con un tecnico</span></h3>
<table width="682">
<tbody>
<tr>
<td style="text-align: center;">
<form action="https://secure.logmeinrescue.com/Customer/Code.aspx" method="post" name="logmeinsupport"><span>Immettere un codice a 6 cifre: </span><br />
<input type="text" name="Code" />
<input type="submit" value="Connetti a tecnico" />
<input type="hidden" name="tracking0" maxlength="64" /> <!-- optional --><br />
<input type="hidden" name="language" maxlength="5" /> <!-- optional --><br />
<input type="hidden" name="hostederrorhandling" /> <!-- optional --></form>
</td>
</tr>
</tbody>
</table>
</div>
<div></div>
<div style="text-align: center;"><em>Per la connessione da Remoto, richiedere il codice telefonando allo<strong> 0445-380175.</strong></em></div>
<div style="text-align: center;"></div>
<div style="text-align: center;"></div>
<div style="text-align: left;"></div>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/generale/assistenza2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Integrazioni CAD con PRO.FILE 8.3 SP7</title>
		<link>http://www.cadtec.it/generale/integrazioni-cad-con-pro-file-8-3-sp7/</link>
		<comments>http://www.cadtec.it/generale/integrazioni-cad-con-pro-file-8-3-sp7/#comments</comments>
		<pubDate>Wed, 28 Mar 2012 02:55:40 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[Generale]]></category>

		<guid isPermaLink="false">http://www.cadtec.it/?p=681</guid>
		<description><![CDATA[E’ stata rilasciata da PROCAD da alcuni mesi la versione PRO.FILE 8.3 SP7 e molti Clienti italiani la stanno utilizzando in produzione. Siamo orgogliosi di annunciare che PRO.FILE (www.profile-plm.it), con il nuovo Service Pack 8.3 SP7, ha aggiornato tutte le integrazioni con le nuove versioni dei sistemi CAD 2012, e nello specifico: SolidWorks 2012 Solid Edge&#160;<a href="http://www.cadtec.it/generale/integrazioni-cad-con-pro-file-8-3-sp7/" class="read-more">Continue Reading</a>]]></description>
			<content:encoded><![CDATA[<p><em>E’ stata rilasciata da PROCAD da alcuni mesi la versione <strong>PRO.FILE 8.3 SP7</strong> e molti Clienti italiani la stanno utilizzando in produzione.<strong> </strong></em></p>
<p><strong>Siamo </strong>orgogliosi di annunciare che <strong>PRO.FILE </strong>(<a href="http://www.profile-plm.it/">www.profile-plm.it</a>), con il nuovo Service Pack <strong>8.3 SP7</strong>, ha aggiornato tutte le integrazioni con le <strong>nuove versioni dei sistemi CAD </strong><strong>2012</strong>, e nello specifico:</p>
<ul>
<li>SolidWorks 2012</li>
<li>Solid Edge ST4</li>
<li>Creo Parametric 1.0</li>
<li>Pro/E Wildfire 5.0</li>
<li>Creo Elements Pro 5.0</li>
<li>Creo Elements Direct Modeling 18 (ex CoCreate Modeling v18)</li>
<li>Inventor 2012</li>
<li>Catia V5 R21</li>
<li>Creo Elements Direct Drafting 18 (ex ME10 v18)</li>
<li>AutoCAD e AutoCAD LT 2012</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/generale/integrazioni-cad-con-pro-file-8-3-sp7/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Disponibile il template mobile per il sito Cadtec</title>
		<link>http://www.cadtec.it/2011/disponibile-il-template-mobile-per-il-sito-cadtec/</link>
		<comments>http://www.cadtec.it/2011/disponibile-il-template-mobile-per-il-sito-cadtec/#comments</comments>
		<pubDate>Mon, 12 Sep 2011 15:07:21 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[2011]]></category>
		<category><![CDATA[Comunicazioni]]></category>

		<guid isPermaLink="false">http://www.cadtec.it/index.php/?p=483</guid>
		<description><![CDATA[Come da richiesta di alcuni utenti, abbiamo provveduto ad attivare un template mobile per navigare nel sito di Cadtec utilizzando uno smartphone o un tablet con sistema operativo Android, Symbian, Windows Mobile, Windows Phone o ios. Il template partirà in automatico quando vi connetterete al sito mediante un terminale portatile. Ne approfittiamo per ricordare a&#160;<a href="http://www.cadtec.it/2011/disponibile-il-template-mobile-per-il-sito-cadtec/" class="read-more">Continue Reading</a>]]></description>
			<content:encoded><![CDATA[<p>Come da richiesta di alcuni utenti, abbiamo provveduto ad attivare un template mobile per navigare nel sito di Cadtec utilizzando uno smartphone o un tablet con sistema operativo Android, Symbian, Windows Mobile, Windows Phone o ios.</p>
<p>Il template partirà in automatico quando vi connetterete al sito mediante un terminale portatile.</p>
<p>Ne approfittiamo per ricordare a tutti i clienti che anche il portale di assistenza ha un suo template mobile cui si può accedere specificando &#8220;/pocket50&#8243; anzichè &#8220;/tech50&#8243; nell&#8217;indirizzo del portale stesso.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/2011/disponibile-il-template-mobile-per-il-sito-cadtec/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Pro.File 8.3 SP6 in arrivo</title>
		<link>http://www.cadtec.it/pro-file/pro-file-8-3-sp6-in-arrivo/</link>
		<comments>http://www.cadtec.it/pro-file/pro-file-8-3-sp6-in-arrivo/#comments</comments>
		<pubDate>Mon, 12 Sep 2011 13:55:33 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[2011]]></category>
		<category><![CDATA[8.3]]></category>
		<category><![CDATA[8.3 SP6]]></category>
		<category><![CDATA[Pro.File]]></category>
		<category><![CDATA[Service Pack]]></category>

		<guid isPermaLink="false">http://www.cadtec.it/index.php/?p=471</guid>
		<description><![CDATA[Procad ha ufficializzato la data di rilascio per il prossimo service pack di Pro.File 8.3. Il giorno dal quale il nuovo SP sarà disponibile è il 22 settembre 2011. Come sempre, appena avremo a disposizione i changelog definitivi, provvederemo a fare un elenco delle migliore apportate nella nuova versione, così da poter permettere a tutti&#160;<a href="http://www.cadtec.it/pro-file/pro-file-8-3-sp6-in-arrivo/" class="read-more">Continue Reading</a>]]></description>
			<content:encoded><![CDATA[<p>Procad ha ufficializzato la data di rilascio per il prossimo service pack di Pro.File 8.3.</p>
<p>Il giorno dal quale il nuovo SP sarà disponibile è il 22 settembre 2011.<br />
Come sempre, appena avremo a disposizione i changelog definitivi, provvederemo a fare un elenco delle migliore apportate nella nuova versione, così da poter permettere a tutti i nostri customer di valutare se applicare o meno il nuovo service pack.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/pro-file/pro-file-8-3-sp6-in-arrivo/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Manutenzione al portale di assistenza</title>
		<link>http://www.cadtec.it/2011/manutenzione-al-portale-di-assistenza/</link>
		<comments>http://www.cadtec.it/2011/manutenzione-al-portale-di-assistenza/#comments</comments>
		<pubDate>Mon, 12 Sep 2011 09:02:09 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[2011]]></category>
		<category><![CDATA[Comunicazioni]]></category>

		<guid isPermaLink="false">http://www.cadtec.it/index.php/?p=478</guid>
		<description><![CDATA[Segnaliamo che durante la giornata odierna potranno esserci problemi nel raggiungere il portale di assistenza Cadtec. La causa del disservizio è da riferirsi ad una manutenzione straordinaria dei server. Ci scusiamo per il disagio, segnalando che i tecnici saranno comunque reperibili telefonicamente o via mail durante tutto il periodo di down del portale. Il down&#160;<a href="http://www.cadtec.it/2011/manutenzione-al-portale-di-assistenza/" class="read-more">Continue Reading</a>]]></description>
			<content:encoded><![CDATA[<p>Segnaliamo che durante la giornata odierna potranno esserci problemi nel raggiungere il portale di assistenza Cadtec.</p>
<p>La causa del disservizio è da riferirsi ad una manutenzione straordinaria dei server.</p>
<p>Ci scusiamo per il disagio, segnalando che i tecnici saranno comunque reperibili telefonicamente o via mail durante tutto il periodo di down del portale.</p>
<p>Il down partirà alle ore 12.30 e terminerà entro e non oltre le ore 13.45</p>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/2011/manutenzione-al-portale-di-assistenza/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Multisite MultiCAD Multilanguage</title>
		<link>http://www.cadtec.it/generale/donec-tempor-libero/</link>
		<comments>http://www.cadtec.it/generale/donec-tempor-libero/#comments</comments>
		<pubDate>Thu, 14 Jul 2011 20:31:03 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[Generale]]></category>

		<guid isPermaLink="false">http://your_website_url_here/?p=77</guid>
		<description><![CDATA[Epta Group Leader mondiale nel settore refrigerazione, utilizza il sistema PDM/PLM Pro.file integrato ai sistemi CAD ed ERP in uso nelle varie sedi remote di Italia (Costan) Francia (Bonnet Nèvè), Regno Unito (George Barker).Implementazione realizzata in 6 MESI. &#160; &#160;]]></description>
			<content:encoded><![CDATA[<p><strong><a href="http://www.eptarefrigeration.com/"><img class="alignnone size-full wp-image-362" title="Gruppo Epta" src="http://cadtec.it/wp-content/uploads/2011/07/eptaprova1.jpg" alt="" width="150" height="151" /></a><br />
Epta Group<br />
</strong></p>
<p>Leader mondiale nel settore refrigerazione, utilizza il sistema PDM/PLM Pro.file integrato ai sistemi CAD ed ERP in uso nelle varie sedi remote di Italia (Costan) Francia (Bonnet Nèvè), Regno Unito (George Barker).Implementazione realizzata in 6 MESI.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/generale/donec-tempor-libero/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>ChangeLog Pro.File 8.3 SP5 [ENG] &#8211; Elenco delle migliorie apportate con il nuovo Service Pack</title>
		<link>http://www.cadtec.it/pro-file/changelog-pro-file-8-3-sp5-eng-elenco-delle-migliorie-apportate-con-il-nuovo-service-pack/</link>
		<comments>http://www.cadtec.it/pro-file/changelog-pro-file-8-3-sp5-eng-elenco-delle-migliorie-apportate-con-il-nuovo-service-pack/#comments</comments>
		<pubDate>Wed, 29 Jun 2011 09:00:57 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[2011]]></category>
		<category><![CDATA[8.3]]></category>
		<category><![CDATA[8.3 SP5]]></category>
		<category><![CDATA[LangPack]]></category>
		<category><![CDATA[Pro.File]]></category>
		<category><![CDATA[Service Pack]]></category>

		<guid isPermaLink="false">http://www.cadtec.it/index.php/?p=437</guid>
		<description><![CDATA[Procad ha rilasciato in questi giorni un nuovo Service Pack per Pro.File 8.3. Il nuovo Sp corregge alcuni piccoli errori e introduce nuove funzionalità. Per Pro.File 8.3 Sp5 è già disponibile anche il pacchetto per la lingua italiana. Sono ora anche disponibili i menu e messaggi aggiornati in lingua italiana per le integrazioni: Alcuni passi&#160;<a href="http://www.cadtec.it/pro-file/changelog-pro-file-8-3-sp5-eng-elenco-delle-migliorie-apportate-con-il-nuovo-service-pack/" class="read-more">Continue Reading</a>]]></description>
			<content:encoded><![CDATA[<p>Procad ha rilasciato in questi giorni un nuovo Service Pack per Pro.File 8.3.<br />
Il nuovo Sp corregge alcuni piccoli errori e introduce nuove  funzionalità.<br />
Per Pro.File 8.3 Sp5 è già disponibile anche il pacchetto per la lingua italiana.<br />
Sono ora anche disponibili i menu e messaggi aggiornati in lingua  italiana per le integrazioni:</p>
<p>Alcuni passi del changelog (eng) sono disponibili dopo il salto.<br />
<img title="Continua..." src="http://www.cadtec.it/wp-includes/js/tinymce/plugins/wordpress/img/trans.gif" alt="" /><br />
<a name="SERVER"><span id="more-437"></span><br />
</a><br />
Changelog</p>
<ul>
<li><a href="#SERVER">Pro.File 8.3 Sp5 Server Component e Pro.File 8.3 Sp4 Windows Client</a></li>
<li><a href="#PROADMIN">Pro.File 8.3 Sp5 Proadmin Console</a></li>
<li><a href="#WEBCLT">Pro.File 8.3 Sp5 Web Client</a></li>
<li><a href="#PROCDES">Pro.File 8.3 Sp5 Process Designer</a></li>
<li><a href="#AUTOCAD">Pro.File 8.3 Sp5 Autocad Integration</a></li>
<li><a href="#CATIA">Pro.File 8.3 Sp5 CATIA V5 Integration</a></li>
<li><a href="#INVENTOR">Pro.File 8.3 Sp5 Inventor Integration</a></li>
<li><a href="#PROE">Pro.File 8.3 Sp5 PRO Engineer Wildfire Integration</a></li>
<li><a href="#SOLIDEDGE">Pro.File 8.3 Sp5 Solid Edge Integration</a></li>
<li><a href="#SOLIDWORKS">Pro.File 8.3 Sp5 SolidWorks Integration</a></li>
<li><a href="#UNIGR">Pro.File 8.3 Sp5 Unigraphics Nx Integration</a></li>
<li><a href="#OFFICE">Pro.File 8.3 Sp5 Microsoft Office Integration</a></li>
<li><a href="#OUTLOOK">Pro.File 8.3 Sp5 Microsoft Outlook Integration</a></li>
<li><a href="#LOTUSN">Pro.File 8.3 Sp5 Lotus Notes Integration</a></li>
<li><a href="#JOBSRV">Pro.File 8.3 Sp5 Job Server NDF</a></li>
<li><a href="#JOBSRVMNT">Pro.File 8.3 Sp5 Job Server Monitor</a></li>
</ul>
<h2><a name="SERVER">Pro.File 8.3 Sp5 Server Component e Profile. 8.3 Sp4 Client:</a></h2>
<p>241.) Request 40839<br />
The quantity bill of materials can now be configured in such way, that fields with dimensional<br />
variations are regarded for grouping. That means if e.g. one part with 2 different dimensions is<br />
assembled 3 times in a CAD model and the bill of materials is derived from this model, 2 positions<br />
with count 3 and one of these dimensions appears in the quantity bill of materials.</p>
<p>242.) Request 41147<br />
When the environment variable &#8220;DoUpdateAutoparBeforeTitleBlock&#8221; is set to the value &#8220;YES&#8221; or with the<br />
aid of the PRO.FILE Management Console parameter &#8220;DO_UPDATE_AUTOPAR_BEFORE_TITLEBLOCK&#8221; it is possible<br />
to define, that when a drawing has been changed and is saved back to PRO.FILE, the parameters are<br />
transferred to PRO.FILE via the AUTOPAR functionality first and the title block is updated afterwards.</p>
<p>243.) Request 41308<br />
When an assembly is saved to PRO.FILE, it is now checked whether or not other versions of the<br />
components are referenced than in the PRO.FILE document structure. If this is the case, the affected<br />
subassemblies are marked as &#8220;locally changed&#8221; and offered for saving to PRO.FILE.</p>
<p>244.) Request 41389<br />
Lookup reference list fields can now also be used in connection with the tool Showlist. If several<br />
values are to be used, they must be separated with comma. However, only the reference list field can<br />
then be used for the search.</p>
<p>245.) Request 41431<br />
For the document list, the evaluation of the configuration of the names of the month has been<br />
corrected in order to display the name of the month in the configured language.<br />
Note: In date fields of the document list it is possible that English names of the month are displayed<br />
instead of German names. The configuration of these list fields must be corrected in the PRO.FILE<br />
Management Console. If this is the case for many fields, this can be done with a direct change in<br />
the database.</p>
<p>246.) Request 41519<br />
When a document favorite searches documents via a status name, e.g. &#8220;In work for fair 2010&#8243;, and this<br />
status does no longer exist, no documents are found and a corresponding message is displayed instead.</p>
<p>247.) Request 41743<br />
When the connection type of a connection is changed from static to dynamic, no more unnecessary SQL<br />
statements are created.</p>
<p>248.) Request 42063<br />
In the Gantt diagram the correct duration is now displayed for tasks that have not been started, even<br />
if the company calendar has been changed afterwards.</p>
<p>249.) Request 42344<br />
It is now possible to move a leading tab, even if this tab was active before.<br />
Note: A leading tab cannot be moved in front of the start and the task page.</p>
<p>250.) Request 42421<br />
When the function lock or unlock is used in the WorkCenter, a function right check is now made.<br />
With this, the user can lock only the documents for which he has the right to do so.</p>
<p>251.) Request 42467<br />
PRO.FILE no longer crashes, even if very large assemblies with thousands of parts are opened from<br />
PRO.FILE.</p>
<p>252.) Request 42499, 40714<br />
Result lists, which have been created via a favorite, are now displayed completely and fill the<br />
entire area of the leading window.</p>
<p>253.) Request 42537<br />
If the creation of a modification entry is configured for the status of a document when a new version<br />
is created, a modification entry is now also requested in the context of the integration function<br />
&#8220;Append version&#8221;.</p>
<p>254.) Request 42545<br />
It is now possible to fill the project status field via the API or via a cross table.</p>
<p>255.) Request 42582<br />
The search for documents via parts using a multi-line field of the part master record now returns<br />
the correct results.</p>
<p>256.) Request 42586<br />
When a file is opened from PRO.FILE and the local file is newer, an inquiry, asking whether or not<br />
the local file should be overwritten, is now displayed in any case.</p>
<p>257.) Request 42607<br />
The PRO.FILE Management Console parameter &#8220;Show a list of documents to lock/unlock&#8221; is now evaluated<br />
correctly, and if it is configured like this, a lock list is displayed when an assembly is initially<br />
saved to PRO.FILE.</p>
<p>258.) Request 42648<br />
If an SQL check function is defined on a reference list field and if it is configured, that this<br />
check function is only to be executed when the form is closed, it is now only executed when the form<br />
is closed.</p>
<p>259.) Request 42657<br />
In the Mail class, methods for special programming have been added.</p>
<p>260.) Request 42711<br />
When additional fields are displayed on a PRO.FILE form, because of an item characteristics class or<br />
a change of the document type, and the form does not offer enough place for those fields, the<br />
scrollbar is now displayed correctly.</p>
<p>261.) Request 42721<br />
When the PRO.FILE Escalation Manager or the PRO.FILE Notification Server try to send an e-Mail and<br />
this does not work, a message is written into the Event Log. This message is now more precise and<br />
points out the error cause to the user.</p>
<p>262.) Request 42723<br />
Changing several documents with different document types in one action now works, because the<br />
document type has no longer to be entered in this case and the changes are thus applied to all<br />
documents.</p>
<p>263.) Request 42724<br />
When a document or the first version of this document is created, different entries are now written<br />
into the database table BIZE_EVENT, so that these two cases can be distinguished.</p>
<p>264.) Request 42738<br />
Bitmap files, that are located in the folders under the path %DBANWPFAD% can now be exchanged, even<br />
if the PRO.FILE Windows Client is running. These bitmap files are used e.g. to display the icons for<br />
the status in PRO.FILE lists.<br />
Note: When the bitmap files, that are located in the folders under the path %DBANWPFAD% are<br />
exchanged, they do not become visible in the PRO.FILE lists before the PRO.FILE Windows Client<br />
has been restarted.</p>
<p>265.) Request 42764<br />
PRO.FILE no longer freezes when, during the creation of a document, the document type is selected via<br />
the tree on the left-hand side and the recently selected document type has the same characteristics<br />
as the currently selected document type.</p>
<p>266.) Request 42768<br />
When documents are searched via part fields, the search now also returns the documents, for which<br />
the newest document version is to be found.</p>
<p>267.) Request 42804<br />
A change of the redlining information is now recognized by PRO.FILE as a change and is therefore<br />
correctly saved back to PRO.FILE.</p>
<p>268.) Request 42805<br />
When the user works with projects, the PRO.FILE windows are now displayed correctly and with the<br />
correct content.</p>
<p>269.) Request 42809<br />
When PRO.FILE meta data are changed, only the contents of the fields, which are configured on the<br />
change form are written into the database.</p>
<p>270.) Request 42822<br />
The bill of materials can now be renumbered without problems in the bill of materials editor, even<br />
if some of the columns have the same title.</p>
<p>271.) Request 42834<br />
The search in multi-line fields now returns the correct results, even if there are numerous multi-line<br />
fields with more than 1000 characters, which do not contain the search string.</p>
<p>272.) Request 42841<br />
If the environment variable SUPRESS_REFRESH_ON_DISCONNECT is set to &#8220;yes&#8221;, PRO.FILE no longer performs<br />
a refresh for the active windows if an integration closes its connection to PRO.FILE.<br />
With this, PRO.FILE is immediately ready to accept a new connection.<br />
Note: When an integration closes the connection to PRO.FILE, no refresh is performed for the active<br />
windows in PRO.FILE. The refresh has to be executed manually, if necessary.</p>
<p>273.) Request 42853<br />
When a version of a document is not linked with a part and a newer version of this document is<br />
linked with a part, this part is now displayed in the usage view of the older document version.</p>
<p>274.) Request 42868<br />
In the context of the conversion of CAD data, the correct date format is now entered into the<br />
document master record when the CAD documents are saved back to PRO.FILE.</p>
<p>275.) Request 42881<br />
The evaluation of the project access rights now works correctly for cumulated superior projects,<br />
and with this, the correct objects are found. In addition, the superior project is now checked,<br />
even if access rights exist.</p>
<p>276.) Request 42883, 42562<br />
Thanks to a program change the Archive Server and the Cache Server should no longer crash.</p>
<p>277.) Request 42913, 42864<br />
If it is configured like this, reference lists on multi-line fields are now displayed in selection<br />
forms and are working correctly.</p>
<p>278.) Request 42914<br />
Even if a PRO.FILE field is filled by a script and the title length of this field is 0, the field<br />
is no longer moved.</p>
<p>279.) Request 42917, 41669, 42815<br />
When changed data are saved back to PRO.FILE via an integration, the PRO.FILE window for entering<br />
and saving the modification log is displayed in the foreground and is ready for the input.</p>
<p>280.) Request 42941<br />
Even if a connection to the PRO.FILE Windows Client is established by the port scanner, telnet etc.,<br />
the PRO.FILE Windows Client works properly and without error message.</p>
<p>281.) Request 42971<br />
When changes are to be saved back, all CAD integrations now only display the locally changed documents<br />
in the PRO.FILE document list and offer them for saving.</p>
<p>282.) Request 42980<br />
The search for documents by expressions like &#8220;today&#8221; (#) now returns the correct results in different<br />
time zones as well.</p>
<p>283.) Request 43025<br />
The user now gets a feedback, if he starts the client-side creation of the neutral format without an<br />
output format being configured for that.</p>
<p>284.) Request 43028<br />
When PRO.FILE is started by an integration and during this action a dialog is displayed, the<br />
integration no longer freezes and the dialog is displayed correctly.</p>
<p>285.) Request 43042<br />
When a reference list is expanded, the number of characters is now used to calculate the display<br />
width. This is not as exact as GDI functions, but uses less time.</p>
<p>286.) Request 43073<br />
When a new window is opened via the object specific editor (open with &#8220;Edit&#8221; -&gt; &#8220;Editor&#8221;) and a<br />
status change is made for one of the objects in this window via the button &#8220;Status change&#8221; in the<br />
main toolbar, no empty message is displayed any longer.</p>
<p>287.) Request 43080<br />
When the function &#8220;New with data&#8221; is applied to a document, to which another document is linked, and<br />
only data of the linked document is changed, then the leading document is not duplicated any longer.</p>
<p>288.) Request 43102<br />
When a PRO.FILE field is filled via a cross table and the form has been scrolled vertically before,<br />
the scrollbar is set to its previous position after the form has been refreshed and the field is<br />
displayed again at the same screen position.</p>
<p>289.) Request 43104, 43394<br />
The dialog for entering the modification comment is now also displayed in the task bar in order to<br />
make it reachable for the user. Furthermore, the mechanism for displaying PRO.FILE data via an<br />
integration has been changed. With this, PRO.FILE should no longer freeze when e.g. the part master<br />
record of a CAD part is to be displayed.</p>
<p>290.) Request 43109, 42309<br />
Sending e-Mails to internal recipients in the context of a status change in the PRO.FILE Web Client<br />
now works properly.</p>
<p>291.) Request 43133, 43233<br />
If the name of the document type is configured language-specifically and is used as a criterion<br />
for a favorite, this favorite now works in all used languages.</p>
<p>292.) Request 43136<br />
When the function Managed Copy is used and drawings are included, these drawings are reloaded from<br />
PRO.FILE, if necessary. During this action PRO.FILE checks whether or not the drawing models of the<br />
first level have the right version. If this is the case the substructure of these drawing models is<br />
not checked and the program assumes, that the locally present versions of the subassemblies and<br />
parts are to be used.</p>
<p>293.) Request 43142<br />
Changing several documents with different document types in one action now works, if only fields of<br />
the fix document master record are changed.</p>
<p>294.) Request 43147<br />
If all of the documents within a version list are of the same document type, the specific fields<br />
for this document type are now displayed correctly.</p>
<p>295.) Request 43158<br />
When a change operation for several positions is aborted in the multi-selection mode of the bill of<br />
materials editor, the parent part of these bill of materials positions is not locked anymore<br />
afterwards.</p>
<p>296.) Request 43189<br />
Thanks to a change in the PRO.FILE database gateway, reference list entries, which contain a double<br />
quote or double prime symbol, can now also be deleted in the PRO.FILE Management Console.</p>
<p>297.) Request 43211<br />
When a file is saved to PRO.FILE via Drag &amp; Drop and attached to a document with a folder, the file<br />
is now added to the folder.<br />
Note: This also applies for Redline files.</p>
<p>298.) Request 43243<br />
When several documents are selected in PRO.FILE for opening, an inquiry is displayed, asking which<br />
of them are to be opened directly in the CAD system after they have been copied to the local working<br />
folder.</p>
<p>299.) Request 43270, 43598<br />
When an object list with several objects is displayed in the leading tab and an object is selected in<br />
the dependent tab &#8220;Browser&#8221; and a status change is made via the icon &#8220;Status change&#8221; , then all of<br />
the objects are now displayed in the leading tab.</p>
<p>300.) Request 43280<br />
The PRO.FILE preview window now works with the AutoVue version 20.1, but no longer with AutoVue<br />
version 20.0!<br />
Note: If the PRO.FILE preview window is used with AutoVue, all of the client computers have to be<br />
updated to the AutoVue version 20.1. If this is not possible, the configuration has to be adapted to<br />
the AutoVue version 20.0. For doing so, the configuration parameter &#8220;ProcadView.AutoVue.Assembly&#8221;<br />
under &#8220;PRO.FILE&#8221; -&gt; &#8220;Document&#8221; -&gt; &#8220;Viewer&#8221; in the PRO.FILE Management Console has to be changed to<br />
the value &#8220;Procad.Profile.Viewer.AutoVue200.dll&#8221;.<br />
If the AutoVue version 20.1 is installed later, the configuration parameter has to be reset to its<br />
original value &#8220;Procad.Profile.Viewer.AutoVue.dll&#8221;.</p>
<p>301.) Request 43295<br />
When a file is saved to PRO.FILE via Drag &amp; Drop and during this action a new version of an existing<br />
PRO.FILE document is to be created, the user exit is now called before the file is actually saved.<br />
With this, the status can be reset early enough, so that the user has the right to change the file.</p>
<p>302.) Request 43304<br />
Even if a status is named language-dependent and a favorite uses the name of such a status as search<br />
criterion, this favorite now works in all languages.</p>
<p>303.) Request 43336<br />
When the transfer of values during the derivation of a bill of materials is defined in a CAD system,<br />
these values are now also transferred if the values are changed afterwards in the CAD system and the<br />
bill of materials is derived again.</p>
<p>304.) Request 43338<br />
If the user has defined grouped list views as default and he wants to select users via the user<br />
selection dialog, this dialog is opened and positioned on the first line as expected.</p>
<p>305.) Request 43352<br />
When an assembly is saved to PRO.FILE, the program checks whether or not a document exists for the<br />
CFG file. If this is the case, the CFG file is saved to this document.</p>
<p>306.) Request 43418<br />
When the version selection is used for the open function, the opened version is displayed with the<br />
folder icon in the dependent list with the existing versions, and the version &#8220;as saved&#8221; is displayed<br />
with the floppy disk icon. With this, it is directly visible for the user, which version is used in<br />
the assembly. In case of version conflicts an exchange of the versions is made generally, because<br />
otherwise it is not possible to open the assembly. For this exchange the highest assembled version<br />
is used.</p>
<p>307.) Request 43426<br />
A new API function has been implemented giving the possibility to check whether or not a user exit<br />
is called within an open transaction.</p>
<p>308.) Request 43436<br />
PRO.FILE now checks directly before the call of a print command of a Format Generator whether or not<br />
a file with the defined fixed file name exists. If this is the case, the file is deleted and the<br />
Format Generator waits until its own file has been created. This makes sure that the correct neutral<br />
document is saved to PRO.FILE.</p>
<p>309.) Request 43455<br />
When the version of a part in an assembly is replaced by another version of this part and the bill of<br />
materials is derived afterwards, a new bill of materials position with the same position number is<br />
created for this part. In addition, all float and string fields of the original bill of materials<br />
position are now taken over, provided that the CAD integration does not hand over values for these<br />
fields. Fields with administrative information e.g. GUID, PPS state etc. are still created anew,<br />
because it is a new bill of materials position.</p>
<p>310.) Request 43460<br />
When transmittals are sent to internal recipients, the P2M file is now created correctly so that the<br />
recipients are able to open this file to display the PRO.FILE objects.</p>
<p>311.) Request 43494<br />
In the CAD/Office browser the first line with the data of the root element is now displayed correctly.</p>
<p>312.) Request 43508<br />
When the user selects the value &#8220;cumulative superior project&#8221; in the field &#8220;guest role&#8221; of a<br />
subordinate project, all of the defined role assignments are now evaluated.</p>
<p>313.) Request 43518<br />
The document list is now also displayed completely for large bills of materials without the need to<br />
scroll to the end before.</p>
<p>314.) Request 43541<br />
When several parts are changed in one action, the selection function is no longer evaluated for the<br />
multi-line fields, but additional properties, which are not depending on the configuration.<br />
With this, regardless of the configured selection function, multi-line fields are only changed if<br />
the user really has changed them.</p>
<p>315.) Request 43560<br />
The Cache Server now only copies the files to the cache area, if they are not up to date there.<br />
This also applies when the environment variable PROCOMPRESS is set.</p>
<p>316.) Request 43581<br />
When the user tries to delete a link between a part and a document and he answers the query whether<br />
or not the link should really be deleted with &#8220;NO&#8221;, then the link is not deleted and the field<br />
contents inherited from the part are no longer cleared.</p>
<p>317.) Request 43599<br />
The printer settings &#8220;printer&#8221;, &#8220;portrait/landscape&#8221; (only for forms), &#8220;paper size&#8221; and<br />
&#8220;border settings&#8221; (only for forms) are now saved in the file %APPDATA%/Procad/Profile/PrintSettings.xml<br />
and can thus be used again for the next printout.</p>
<p>318.) Request 43605<br />
The integration function &#8220;Display Drawing&#8221; now works error-free, even if there are a lot of drawings<br />
in the local working folder.</p>
<p>319.) Request 43659<br />
When the extended bill of materials is refreshed via the key F5, the first line with the parent part<br />
now stays.</p>
<p>320.) Request 43706<br />
When an object is created, all fields are now filled according to the configuration via a cross table,<br />
even if a check function is defined on the form and this check function returns an error.</p>
<p>321.) Request 43717<br />
In the WorkCenter the working folder can no longer be changed, if it is only in viewing mode.</p>
<p>322.) Request 43736<br />
When bill of materials positions are renumbered, a modification date is now entered.</p>
<p>323.) Request 43778<br />
The project list is now displayed sorted, e.g. when the user searched via the project name.<br />
In the results the newest project is always at the  top of the list.</p>
<p>324.) Request 43781<br />
The order of the variable part master data in the database no longer has consequences for the change<br />
of part master data. With this, the changes are taken over and written correctly into the database.</p>
<p><a name="PROADMIN"> </a></p>
<h2><a name="PROADMIN">Pro.File 8.3 Sp4 Proadmin Console</a></h2>
<p>048.) Request 41431<br />
In the PRO.FILE Management Console the configuration with English and German names of the month has<br />
been switched in order to match the display and the behavior in the context of the form view.<br />
With this, there is no change necessary for the date fields in the form view and future configurations<br />
can be done according to the display. For the document list, the evaluation of the configuration of<br />
the names of the month has been corrected in order to display the name of the month in the configured<br />
language.<br />
Note: In date fields of the document list it is possible that English names of the month are displayed<br />
instead of German names. The configuration of these list fields must be corrected in the PRO.FILE<br />
Management Console. If this is the case for many fields, this can be done with a direct change in<br />
the database.</p>
<p>049.) Request 42616<br />
When an output format is not supported for the creation of neutral formats, a message is displayed.<br />
This message is now suitable, even if the method &#8220;SaveAs&#8221; is used for the format generation.</p>
<p>050.) Request 42824<br />
For the users listed under the node &#8220;Configuration&#8221; -&gt; &#8220;User parameter&#8221; no properties can be displayed<br />
or changed. For this reason, the menu item &#8220;Configuration&#8221; -&gt; &#8220;Properties&#8221; has been deactivated.</p>
<p>051.) Request 42865<br />
In the form designer it is now possible to delete the form set 0, if at least one other form<br />
set exists.</p>
<p>052.) Request 43267<br />
When the user changes the name of a control on a form in an older PRO.FILE release and exports this<br />
form, the form definitions and fields are now written correctly into the database for another form<br />
during an import of this form. With this, the objects of such a form remain visible after the form<br />
has been changed and saved.</p>
<p>053.) Request 43372, 42882<br />
The maximum waiting time in the printer configuration for the Format Generators was increased to<br />
14400 seconds (4 hours) and the default is set to 120 seconds.</p>
<p><a name="WEBCLT"> </a></p>
<h2><a name="WEBCLT">Pro.File 8.3 Sp4 Web Client</a></h2>
<p>028.) Request 42210<br />
      If a project is duplicated and the field &#8220;Guest role&#8221; is not defined on the creation form, the default<br />
      value &#8220;user&#8221; is now entered for the guest role. This is required, because otherwise the project is no<br />
      longer visible in PRO.FILE.<br />
      Note: Since the implementation of the status management for projects, the field &#8220;Guest role&#8221; cannot be<br />
      changed during creation, because projects would not be visible in PRO.FILE afterwards. When a project<br />
      is changed, another value for the field &#8220;Guest role&#8221; can be entered, because in this context<br />
      additional checks are made (e.g. role assignments, superior project, etc.).</p>
<p>029.) Request 42335<br />
      In the status administration the access permissions of the functional user &#8220;AUTOR&#8221; are now evaluated<br />
      correctly for projects.</p>
<p>030.) Request 42346<br />
      Updating files or documents via an integration now also works correctly when role assignments are<br />
      used for projects.</p>
<p>031.) Request 42063<br />
      In the Gantt diagram the correct duration is now displayed for tasks that have not been started, even<br />
      if the company calendar has been changed afterwards.</p>
<p>032.) Request 42547<br />
      On the start page, the icon next to the field for the full-text search is now displayed correctly,<br />
      even if the user switches to part, document or project in the selection box.</p>
<p>033.) Request 42935<br />
      A list view, which is set as default in the PRO.FILE Windows Client is now also used in the<br />
      PRO.FILE Web Client.</p>
<p>034.) Request 43109, 42309<br />
      Sending e-Mails to internal recipients in the context of a status change in the PRO.FILE Web Client<br />
      now works properly.</p>
<p>035.) Request 43508<br />
      When the user selects the value &#8220;cumulative superior project&#8221; in the field &#8220;guest role&#8221; of a<br />
      subordinate project, all of the defined role assignments are now evaluated.</p>
<p>036.) Request 43778<br />
      The project list is now displayed sorted, e.g. when the user searched via the project name.<br />
      In the results the newest project is always at the  top of the list.</p>
<p><a name="PROCDES"> </a></p>
<h2><a name="PROCDES">Pro.File 8.3 Sp4 Process Designer</a></h2>
<p>001.) Request 39638<br />
      In the English version of the setup the correct product name is now displayed throughout the dialogs.</p>
<p>002.) Request 40680<br />
      When the PRO.FILE Process Designer is to be used with Visio 2010, its setup now checks whether or<br />
      not the .NET programmability support is installed on the computer. If not, an error message is<br />
      displayed and the setup aborts.</p>
<p><a name="AUTOCAD"> </a></p>
<h2><a name="AUTOCAD">Pro.File 8.3 Sp4 Autocad Integration</a></h2>
<p>17.) Request 43256<br />
Updating the drawing title block of a drawing with external references (drawing and pixel image)<br />
now works error-free.</p>
<p><a name="CATIA"> </a></p>
<h2><a name="CATIA">Pro.File 8.3 Sp4 CATIA V5 Integration</a></h2>
<p>10.) Request 43678<br />
Drawings, which reference parts or assemblies via HybridBodies, can now also be saved to PRO.FILE.</p>
<p><a name="INVENTOR"> </a></p>
<h2><a name="INVENTOR">Pro.File 8.3 Sp4 Inventor Integration</a></h2>
<p>17.) Request 42353<br />
In the Managed Copy dialog, components that are locked by another user are now displayed and can<br />
thus be copied.</p>
<p>18.) Request 42542<br />
Before a component is opened from PRO.FILE, all components in the session are now updated.<br />
This makes sure that always the newest components are loaded before the opening action.</p>
<p>19.) Request 42618<br />
When a bill of materials is inserted on a drawing, Inventor no longer crashes, even if a lot of<br />
positions (&gt;20) are set to &#8220;Bill of materials irrelevant&#8221; in the PRO.FILE bill of materials</p>
<p>20.) Request 42656<br />
When an assembly contains instances, that are referencing from different folders to the same part<br />
family, and this assembly is saved to PRO.FILE, a message is displayed during the reading of the<br />
structure, pointing out this fact to the user, and the save action is aborted.</p>
<p>21.) Request 42674<br />
The integration no longer reads PRO.FILE Management Console parameters, which are not needed.<br />
With this, the integration commands should be executed faster.</p>
<p>22.) Request 42880<br />
The setup for the  Inventor Integration now installs the integration correctly, and as a result,<br />
the PRO.FILE menu is available in Inventor after the installation.</p>
<p>23.) Request 42907<br />
An assembly with derivations, whose references to the parent part are broken, can now also be saved<br />
to PRO.FILE without problems.</p>
<p>24.) Request 43062<br />
When iPart or iAssembly instances are inserted via the command &#8220;Insert part&#8221;, the corresponding<br />
CAD files are now copied to a subfolder of the local working folder. This subfolder is named after<br />
the part family. When the instances are saved back to PRO.FILE, they are now recognized as PRO.FILE<br />
documents.</p>
<p>25.) Request 43219<br />
When the function &#8220;Insert bill of materials&#8221; is used, Inventor no longer crashes, even if the<br />
PRO.FILE Management Console parameter &#8220;Update/Sort parts list on drawing&#8221; is set to the value<br />
&#8220;NO_UPDATE&#8221;.</p>
<p>26.) Request 43383<br />
When an assembly is opened from PRO.FILE, Inventor no longer crashes, even if the recently active<br />
detail precision cannot be read.</p>
<p><a name="PROE"> </a></p>
<h2><a name="PROE">Pro.File 8.3 Sp4 PRO Engineer Wildfire Integration</a></h2>
<p>24.) Request 42453<br />
If the environment variable &#8220;CHECK_MODELS_IN_SESSION_AFTER_RETRIEVE_ONLY_ON_NDF&#8221; is set to the value<br />
&#8220;YES&#8221;, the Pro/ENGINEER models are checked for errors during the opening action, and no neutral format<br />
is created if the models are faulty.<br />
Note: This hotfix only makes sense in the context of the Format Generator.</p>
<p>25.) Request 42607<br />
The PRO.FILE Management Console parameter &#8220;Show a list of documents to lock/unlock&#8221; is now evaluated<br />
correctly, and if it is configured like this, a lock list is displayed when an assembly is initially<br />
saved to PRO.FILE.</p>
<p>26.) Request 42664<br />
For the Format Generator, the neutral format STEP is now also created correctly for assemblies<br />
and parts.</p>
<p>27.) Request 43153<br />
If it is configured via the PRO.FILE Management Console parameter &#8220;Update BOM during save&#8221;, the<br />
function &#8220;Save BOM&#8221; no longer adds suppressed components, that are not loaded in the system memory,<br />
to the bill of materials.</p>
<p>28.) Request 43466<br />
When Pro/ENGINEER data is saved to PRO.FILE, an automatic connection between the CAD document and an<br />
existing part master record can be configured. This is now possible by using the number as well as the<br />
name of a part master record field, i.e. in both cases the matching part master records are found,<br />
if they exist.</p>
<p>29.) Request 43711<br />
The menu item &#8220;Open all drawings&#8221; has been added to the menu. With this it is possible to open all<br />
drawings, which are included in the structure of the active model.<br />
Note: Only the drawing for the active model is opened. All other drawings are copied to the local<br />
working folder.</p>
<p>30.) Request 43717<br />
In the WorkCenter the working folder can no longer be changed, if it is only in viewing mode.</p>
<p><a name="SOLIDEDGE"> </a></p>
<h2><a name="SOLIDEDGE">Pro.File 8.3 Sp4 Solidedge Integration</a></h2>
<p>35.) Request 42341, 42516<br />
After the integration function &#8220;Replace component&#8221; has been used, the Solid Edge function &#8220;Open&#8221;<br />
remains active and works without problems.</p>
<p>36.) Request 42395<br />
The creation of a position number in a drawing now works, even if parts are missing in the structure<br />
or if parts are grouped in the EdgeBar.</p>
<p>37.) Request 42783<br />
When a drawing is in background mode and a neutral format has to be created from this drawing, no more<br />
message is now displayed.</p>
<p>38.) Request 42861<br />
When a neutral document is created, it is now saved to the correct folder and therefore saved correctly<br />
in PRO.FILE.</p>
<p>39.) Request 42875, 43325, 42704<br />
When a subassembly is selected in the Edge Bar and the user tries to display the corresponding part<br />
master record in PRO.FILE, this part master record is displayed properly and without prior error<br />
message.</p>
<p>40.) Request 42889<br />
Parts of a Solid Edge assembly can now only be replaced by Solid Edge documents.</p>
<p>41.) Request 42974<br />
After a drawing is opened, the Solid Edge file properties are now updated by the Solid Edge<br />
integration. With this, the Solid Edge file properties can be used for updating the drawing title<br />
block.</p>
<p>42.) Request 43091<br />
In the context of an assembly the function &#8220;Display drawing&#8221; now displays the drawing of this assembly.</p>
<p>43.) Request 43224<br />
Some commands of the Solid Edge integration check whether or not the referenced files match the file<br />
names of the assembly components. If an inconsistency is found, the integration assumes that the name<br />
of the assembly component is not updated correctly. In this case the document is loaded and its file<br />
name is checked. This behavior results in a little performance loss. But since the documents are only<br />
loaded for the components, for which the file names are returned incorrectly, this should only lead<br />
to a noticeable delay in exceptional cases.</p>
<p>44.) Request 43225, 43602, 43590, 43591<br />
When the user aborts the function &#8220;Replace Part&#8221; or &#8220;Insert Part&#8221;, no more error message is displayed<br />
in the CAD system and the function can be used again.</p>
<p>45.) Request 43243<br />
When several documents are selected in PRO.FILE for opening, an inquiry is displayed, asking which<br />
of them are to be opened directly in the CAD system after they have been copied to the local working<br />
folder.</p>
<p>46.) Request 43354<br />
In the context of the function &#8220;Managed Copy&#8221; the selected documents have to be renamed, and for<br />
doing this, they must be closed and opened again. During this action the connection to PRO.FILE no<br />
longer gets lost and the function &#8220;Managed Copy&#8221; works properly.</p>
<p>47.) Request 43435<br />
When decimal numbers are in Solid Edge text fields and they are transferred to PRO.FILE via the AUTOPAR<br />
functionality and variable fields, the decimal places are now transferred correctly.</p>
<h2><a name="SOLIDWORKS">Pro.File 8.3 Sp4 SolidWorks Integration</a></h2>
<p>35.) Request 42551<br />
SolidWorks documents, that are saved in PRO.FILE, are now correctly recognized as PRO.FILE documents<br />
by the integration, because the upper and lower case spelling of the property procad@dokid is ignored.</p>
<p>36.) Request 42727<br />
The file property containing the PRO.FILE ID is no longer evaluated for drawings.<br />
Note: For parts and assemblies the configuration-specific file property containing the PRO.FILE ID<br />
is still required. If this property is deleted, the user is still requested to create a document<br />
for an instance.</p>
<p>37.) Request 42789<br />
When a drawing and a part have the same name and the drawing is saved to PRO.FILE immediately after<br />
the part, the Check-In wizard now displays the thumbnail of the drawing.</p>
<p>38.) Request 42904<br />
The check of the file properties when saving assemblies or parts was deactivated. With this,<br />
assemblies which contain VarBox parts can be saved in PRO.FILE.</p>
<p>39.) Request 43085<br />
When the references are read from SolidWorks, the spelling of the corresponding file names concerning<br />
lower/upper case is transferred like it is returned from the SolidWorks API.<br />
Note: SolidWorks assemblies take over the spelling for components at the moment these components are<br />
inserted. If the spelling of a component is changed afterwards, SolidWorks does not take over this<br />
change, because it is not relevant for the loading of the component. Because the SolidWorks integration<br />
takes over the spelling of assembly components like it is returned from SolidWorks, it may still happen<br />
that a later changed spelling is not taken over in PRO.FILE.</p>
<p>40.) Request 43243<br />
When several documents are selected in PRO.FILE for opening, an inquiry is displayed, asking which<br />
of them are to be opened directly in the CAD system after they have been copied to the local working<br />
folder.</p>
<p>41.) Request 43512<br />
Even if an assembly that is opened from PRO.FILE has several configurations, it remains open.</p>
<h2><a name="UNIGR"></a></h2>
<h2><a name="UNIGR">Pro.File 8.3 Sp4 Unigraphics Nx Integration</a></h2>
<p>20.) Request 43086<br />
After the client-side creation of the neutral format, the connection to PRO.FILE is now released<br />
properly, so that the user can continue working with PRO.FILE.</p>
<p>21.) Request 43345<br />
When a part family is saved to PRO.FILE, this action now works error-free, because the Generic can<br />
now be renamed properly.</p>
<h2><a name="OFFICE"></a></h2>
<h2><a name="OFFICE">Pro.File 8.3 Sp4 Microsoft Office Integration</a></h2>
<p>016.) Request 42737<br />
If it is configured like this, the file name is now entered reliably as original name into the<br />
document master record in PRO.FILE.</p>
<h2><a name="OUTLOOK"></a></h2>
<h2><a name="OUTLOOK">Pro.File 8.3 Sp4 Microsoft Outlook Integration</a></h2>
<p>012.) Request 43515<br />
When a document is changed via the Outlook integration, the document master record is also changed,<br />
and the version key of the integration, e.g. MS Outlook-2000, is now entered correctly.</p>
<p>013.) Request 43615<br />
The PRO.FILE Management Console parameter &#8220;Replace original mail&#8221; can now also be set to the value<br />
&#8220;ASK&#8221;.  With this, the user has the possibility to decide himself whether or not an e-Mail is to be<br />
replaced.</p>
<p>014.) Request 43617<br />
The format of the local e-Mail is not changed anymore, when the e-Mail has been saved to PRO.FILE and<br />
has been extended by the text, that gives the user the information about the database, in which the<br />
e-Mail has been saved and the document ID, under which the e-Mail has been saved.</p>
<h2><a name="LOTUSN"></a></h2>
<h2><a name="LOTUSN">Pro.File 8.3 Sp4 Lotus Notes Integration</a></h2>
<p>03.) Request 43515<br />
When a document is changed via the Lotus Notes 8 integration, the document master record is also<br />
changed, and the version key of the integration, e.g. Lotus Notes 8, is now entered correctly.</p>
<h2><a name="JOBSRV"></a></h2>
<h2><a name="JOBSRV">Pro.File 8.3 Sp4 Job Server NDF</a></h2>
<p>005.) Request 43113<br />
      When the Format Generator processes a task, it now checks whether temporary working folders still<br />
      exist from previous tasks. If this is the case, these temporary working folders are deleted.</p>
<p>006.) Request 43571<br />
      The PRO.FILE Job Server now also works correctly in the context of Solid Edge x64 and the Format<br />
      Generator for Solid Edge.</p>
<h2><a name="JOBSRVMNT"></a></h2>
<h2><a name="JOBSRVMNT">Pro.File 8.3 Sp4 Job Server Monitor</a></h2>
<p>007.) Request 42975, 43045, 43068, 42806<br />
      In the monitor for the Job Server the correct dates for the creation and finish date are now also<br />
      displayed on a German operating system.</p>
<p>008.) Request 43681<br />
      In the monitor for the Job Server the time zone is now regarded in date fields with displayed time.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/pro-file/changelog-pro-file-8-3-sp5-eng-elenco-delle-migliorie-apportate-con-il-nuovo-service-pack/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Rilasciato Pro.File 8.3 SP5 &#8211; Elenco certificazioni</title>
		<link>http://www.cadtec.it/pro-file/rilasciato-pro-file-8-3-sp5-elenco-certificazioni/</link>
		<comments>http://www.cadtec.it/pro-file/rilasciato-pro-file-8-3-sp5-elenco-certificazioni/#comments</comments>
		<pubDate>Wed, 29 Jun 2011 08:20:43 +0000</pubDate>
		<dc:creator>Cadtec</dc:creator>
				<category><![CDATA[2011]]></category>
		<category><![CDATA[8.3]]></category>
		<category><![CDATA[8.3 SP5]]></category>
		<category><![CDATA[Pro.File]]></category>
		<category><![CDATA[Service Pack]]></category>

		<guid isPermaLink="false">http://www.cadtec.it/index.php/?p=431</guid>
		<description><![CDATA[In data 29/06/2011 PROCAD ha rilasciato un nuovo Service Pack per il PDM-PLM Multicad Pro.File. Le certificazioni comprendono: SERVER OS\DB: Windows Server 2008 x64 SP2 Windows Server 2008 R2 x64 SQL Server 2008 x64 SQL Server 2008 R2 x64 Oracle 11g Release 1 x64 (11.1.0.x.0) Oracle 11g Release 2 x64 (11.2.0.x.0) Sistemi Operativi Client: Windows&#160;<a href="http://www.cadtec.it/pro-file/rilasciato-pro-file-8-3-sp5-elenco-certificazioni/" class="read-more">Continue Reading</a>]]></description>
			<content:encoded><![CDATA[<p>In data 29/06/2011 PROCAD ha rilasciato un nuovo Service Pack per il PDM-PLM Multicad Pro.File.</p>
<p>Le certificazioni comprendono:</p>
<p><span id="more-431"></span></p>
<p>SERVER OS\DB:</p>
<ul>
<li>Windows Server 2008 x64 SP2</li>
<li>Windows Server 2008 R2 x64</li>
<li>SQL Server 2008 x64</li>
<li>SQL Server 2008 R2 x64</li>
<li>Oracle 11g Release 1 x64 (11.1.0.x.0)</li>
<li>Oracle 11g Release 2 x64 (11.2.0.x.0)</li>
</ul>
<p>Sistemi Operativi Client:</p>
<ul>
<li>Windows XP SP3</li>
<li>Windows XP x64 SP3</li>
<li> Windows 7</li>
<li>Windows 7 x64</li>
</ul>
<p>&nbsp;</p>
<p>-Integrazioni CAD-</p>
<p style="padding-left: 30px;">Autocad &#8211; : regular version, Mechanical version e Mechanical Power Pack</p>
<ul>
<li>AutoCAD 2009</li>
<li>AutoCAD 2010</li>
<li>AutoCAD 2010 x64</li>
<li>AutoCAD 2011</li>
<li>AutoCAD 2011 x64</li>
<li>AutoCAD 2012</li>
<li>AutoCAD 2012 x64</li>
</ul>
<p style="padding-left: 30px;">Catia:</p>
<ul>
<li>Catia V5 R18</li>
<li>Catia V5 R18 x64</li>
<li> Catia V5 R19</li>
<li>Catia V5 R19 x64!</li>
</ul>
<p style="padding-left: 30px;">&nbsp;</p>
<p style="padding-left: 30px;">CoCreate Drafting:</p>
<ul>
<li>CoCreate Drafting Version 2007 (15.5)</li>
<li>CoCreate Drafting Version 2008 (16.0)</li>
<li>Creo Elements/Direct Drafting 17</li>
</ul>
<p style="padding-left: 30px;">Inventor:</p>
<ul>
<li>Inventor 2009</li>
<li>Inventor 2009 x64</li>
<li>Inventor 2010</li>
<li>Inventor  2010 x64</li>
<li>Inventor 2011</li>
<li>Inventor 2011 x64</li>
<li>Inventor 2012</li>
</ul>
<p style="padding-left: 30px;">Microstation:</p>
<ul>
<li>Microstation 8.5</li>
<li>Microstation XM (8.9)</li>
<li>Microstation 8i</li>
</ul>
<p style="padding-left: 30px;">&nbsp;</p>
<p style="padding-left: 30px;">Pro/Engineer:</p>
<ul>
<li>Pro/Engineer Wildfire 3.0</li>
<li>Pro/Engineer Wildfire 3.0 x64</li>
<li>Pro/Engineer Wildfire 4.0</li>
<li>Pro/Engineer Wildfire 4.0 x64</li>
<li>Pro/Engineer Wildfire 5.0</li>
<li>Pro/Engineer Wildfire 5.0 x64</li>
</ul>
<p style="padding-left: 30px;">&nbsp;</p>
<p style="padding-left: 30px;">Solid Edge (tutti gli MP):</p>
<ul>
<li>Solid Edge V20</li>
<li>Solid Edge ST</li>
<li>Solid EdgeST x64</li>
<li>Solid Edge ST2</li>
<li>Solid Edge ST2 x64</li>
</ul>
<p style="padding-left: 30px;">SolidWorks (tutti gli MP\SP se non specificato):</p>
<ul>
<li>SolidWorks 2010 (da SP4)</li>
<li>SolidWorks 2010 x64 (da SP4)</li>
<li>SolidWorks 2011</li>
<li>SolidWorks 2011 x64</li>
</ul>
<p style="padding-left: 30px;">Unigraphics:</p>
<ul>
<li>Unigraphics NX 5.0</li>
<li>Unigraphics NX 5.0 x64</li>
<li>Unigraphics NX 6.0</li>
<li>Unigraphics NX 6.0 x64</li>
<li>Unigraphics NX 7.5</li>
<li>Unigraphics NX 7.5 x64</li>
</ul>
<p>&nbsp;</p>
<p>Office ed E-Mail:</p>
<p style="padding-left: 30px;">Lotus Notes:</p>
<ul>
<li>Lotus Notes 8.0.1</li>
<li>Lotus Notes 8.5</li>
</ul>
<p style="padding-left: 30px;">Microsoft Office (SP <span style="text-decoration: underline;">MINIMO</span> specificato):</p>
<ul>
<li>MS Office XP SP3</li>
<li>MS Office 2003 SP3</li>
<li>MS Office 2007 SP1</li>
<li>MS Office 2010</li>
</ul>
<p style="padding-left: 30px;">&nbsp;</p>
<p style="padding-left: 30px;">Microsoft Outlook (SP MINIMO specificato):</p>
<ul>
<li>MS Outlook XP SP3</li>
<li>MS Outlook 2003 SP3</li>
<li> MS Outlook 2007 SP1</li>
<li>MS Outlook 2010</li>
</ul>
<p>Sono disponibili ulteriori integrazioni con CAD meccacini, CAD Elettrici e programmi E-mail.<br />
Se interessati a ricevere ulteriori informazioni, vi preghiamo di <a title="Contattaci" href="../contatti/13-2/" target="_blank">contattarci</a>.</p>
<p>Sono come sempre disponibili, per tutte le integrazioni certificate, pacchetti per la generazione e l&#8217;archiviazione automatica di formati neutri (PDF, DXF, TIF, etc) sia per i programmi CAD che per quelli di produttività personale o e-mail.</p>
<p>Con questo Service Pack, sono stati rilasciati aggiornamenti anche per le integrazioni con i sistemi ERP (esempio SAP, etc.), così come nuovi updates per il servizio di condivisione dati via web, quello di compressione dati, il sistema di gestione con cache server e per le sedi remote, e tutti gli altri pacchetti che formano il mondo di Pro.File.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p style="padding-left: 30px;">&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.cadtec.it/pro-file/rilasciato-pro-file-8-3-sp5-elenco-certificazioni/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

